The alkaline cleaning chemical for RO membranes provided by TVTS has the trade name “Membrane cleaner AA”. Membrane cleaner AA is a strong alkaline cleaning solution (pH 13 – 14), used to remove organic substances, such as grease, microorganisms on the membrane.

1. Features: Removes organic substances, grease and microorganisms.

Hóa chất tẩy rửa màng RO; Membrane cleaner AA
RO membrane cleaning chemicals, 25 liter can

2. Product information:

  • Trade Name: Membrane cleaner AA
  • Manufacturer: ROMACO – German brand
  • Origin: Netherlands
  • Specification: 25 liters/can or 210 liters/drum
  • Physical properties: Liquid, light yellow, with characteristic odor
  • PH value at 20 ° C: 12.5 – 13.5
  • Melting point / freezing point: > 0 ° C
  • Initial boiling point and boiling range: Not determined
  • Flash point: Not applicable.
  • Decomposition temperature: Not determined.
  • Automatic ignition temperature: The product does not spontaneously ignite.
  • Explosive properties: The product does not present an explosion hazard.
  • Vapor pressure at 20 ° C: 23 hPa
  • Density at 20 ° C: 1.08 – 1.10 g / cm³
  • Solubility in / Miscibility with: Completely soluble in water
  • Partition coefficient: n-octanol / water: Not determined.
  • Composition: Anionic surfactant; Sodium Hydroxide (NaOH); Tetrasodium EDTA (tetrasodium ethylenediaminetetraacetate).
  • Oxidizing properties: Not determined

3. Instructions for use

When using chemicals to clean the RO/NF/UF/MF membrane periodically, it is necessary to check the exact condition of the filter membrane. Mix Membrane Cleaner AA with water at the appropriate ratio and check to maintain the pH index at 11 – 12.

4. First aid instructions for improper contact with chemicals

  • First: Immediately remove clothing contaminated with the product
  • In case of inhalation: Help remove as much of the solution from the airway as possible, provide fresh air. Take to the nearest medical facility.
  • In case of skin contact: Immediately wash thoroughly with water and soap.
  • In case of eye contact: Open eyes and rinse thoroughly under running water for several minutes. Then go to the nearest medical facility.
  • In case of swallowing/drinking: Drink plenty of water and provide fresh air. Then go to the nearest medical facility.